UPS Powercom SNT-1500

#5358662

UPS Powercom SNT-1500

[double conversion, 1500 VA, 1500 W, 6 x IEC 320 C13 (computer), RS-232, RS-485, USB] details

Not on sale

  • Characteristics
  • Feedback 0
  • Instructions and files

Characteristics UPS Powercom SNT-1500

General parameters

Type
UPS
Model
Powercom SNT-1500
Main Color
black
Type
double conversion
Form Factor
Rack/Tower

Technical parameters

Maximum Output Power
1500 VA
Effective Power Output
1500 W
Minimum Input Voltage
208 V
Max Input Voltage
240 V
Min Input Frequency
50 Hz
Max Input Frequency
60 Hz
Output Voltage Stability
± 2 %
Minimum Output Frequency
50 Hz
Max Output Frequency
60 Hz
Wave Form
pure sine wave
Delay When Switching to Battery
0 ms
Safety Features
short-circuit protection, overcharge protection, overload protection

Connectors

Number and Type of Power Output Connectors
6 x IEC 320 C13 (computer)
Number of Power Output Connectors (UPS)
6
Connectors/Ports
USB, RS-485, RS-232
Port Layout
rack-mounted

Battery

Battery Type
lead-acid
Battery Voltage and Capacity
12V/9Ah
Replaceable Batteries
yes
Battery Hot Swap
yes
External Battery Connection
yes

Additional Information

Functions and Modes
bypass
Cold Start
yes
Display
LCD display
LED Indicators
battery-powered
Sound Signals
UPS fault (error), overload, low battery level, battery-powered
Operating Temperature
from 0 to +40°C
Package Contents
fastening kit, power cable, RS-232 cable, documentation, software disk

Dimensions and Weight

Depth
425 mm
Width
428 mm
Height
84 mm
Weight
9.5 kg

Description

The Powercom SNT-1500 UPS with a 1500 VA output capacity is used for the uninterruptible power supply of servers, computer equipment, medical, household, and telecommunication devices. Double-conversion technology eliminates mains interference, stabilizes voltage, and instantly transfers connected devices to battery power during outages.
The UPS features a hot-swappable battery option, allowing you to replace the battery without shutting down the equipment. External batteries can be connected to the device to extend autonomous runtime. The cold start function allows using the UPS as a generator, which is convenient when power is out and you need to save files on a computer, charge a phone, or print documents. Data on the Powercom SNT-1500 operation, errors, and charge level are shown on the display. The model is equipped with overload and short-circuit protection. The battery automatically stops charging upon reaching full capacity, extending battery life.