vertically from the remote, horizontal from the remote
Automatic Airflow Direction
yes
Stores Last Louvre Position
yes
iFEEL Feature (Follow Me)
yes
Human Presence Sensor
none
Warm-Start Feature
yes
Auto Restart
yes
Auto Malfunction Check-Up
yes
Self-Cleaning
self-cleaning
Standby Heating
yes
Air Purification
Filters
carbon, catalytic, preliminary (coarse) cleaning
Ionization
none
Ultraviolet Lamp
none
Fresh Air Intake
none
Control and Display
Timer
yes
Timer Functions
turn on/off
Max Timer Setting Time
24 h
Display
concealed
Control via Mobile Device
none
Mounting
Liquid Line Diameter
6.35 mm
Gas Line Diameter
9.52 mm
Max Pipeline Length
20 m
Max Unit Elevation Gap
10 m
Safety
Outdoor Temperature Range in Cooling Mode
min. 0°C, max. 46°C
Outdoor Temperature Range in Heating Mode
max. 24°C, min. -15°C
Protection
corrosion resistance, refrigerant leak
Power Specifications
Energy Consumption Class (Cooling)
A
Energy Efficiency Class (Heating)
A
Power Supply
from mains
Power Supply Voltage
220-240 V / 50 Hz
Power Consumption During Cooling
705 W
Power Consumption (Heating)
610 W
Additional Information
Package Contents
remote controller
Extra
wi-fi module is sold separately, remote control backlight, Dimmer feature, Blue Fin heat exchanger protective coating
Indoor Unit Dimensions and Weight
Indoor Unit Width
790 mm
Indoor Unit Height
255 mm
Indoor Unit Depth
197 mm
Indoor Unit Weight
7.25 kg
Outdoor Unit Dimensions and Weight
Outdoor Unit Width
660 mm
Outdoor Unit Height
482 mm
Outdoor Unit Depth
240 mm
Outdoor Unit Weight
20.9 kg
Packaged Dimensions and Weight
Box Width
850 mm
Box Height
850 mm
Box Depth
315 mm
Weight Boxed
30.1 kg
Description
The capacity of the CHERBROOKE ASV-07UR4K1/AOV-07UR4K1 wall-mounted air conditioner is sufficient to serve a room area of 23 m². In automatic mode, the split system alternates between dehumidification, heating, and cooling modes depending on the room's temperature and humidity. Using the remote control, you can adjust the louver position, operating intensity, and other settings. The model is equipped with a 24-hour timer, a warm start function to prevent drafts during heating, and a Follow Me feature to monitor air parameters via sensors on the remote.
In standby heating mode, the air conditioner maintains an above-zero temperature and protects the house from freezing during long absences. In the event of power outages, the system automatically resumes operation with the last saved settings. The white CHERBROOKE ASV-07UR4K1/AOV-07UR4K1 split system is enhanced with connection port protection against transport damage and an anti-corrosion coating on the heat exchangers. The system alerts to the risk of refrigerant leaks and other operational issues and can run self-diagnostics to detect malfunctions.