UPS Ippon Na+ TA 10K

#9339151

UPS Ippon Na+ TA 10K

[double conversion, 10000 VA, 10000 W, terminal block, EPO, RS-232, SNMP slot, USB Type B] details

Not on sale

  • Characteristics
  • Feedback 0
  • Instructions and files

Characteristics UPS Ippon Na+ TA 10K

General parameters

Type
UPS
Model
Ippon Na+ TA 10K
Manufacturer Code
[2049882]
Main Color
white
Type
double conversion
Form Factor
Tower
Power Cable Length
0 m

Technical parameters

Maximum Output Power
10000 VA
Effective Power Output
10000 W
Minimum Input Voltage
110 V
Max Input Voltage
300 V
Min Input Frequency
40 Hz
Max Input Frequency
70 Hz
Output Voltage Stability
± 1 %
Minimum Output Frequency
49.9 Hz
Max Output Frequency
60.1 Hz
Wave Form
pure sine wave
Runtime
3.5 min (10000W)
Delay When Switching to Battery
0 ms
Max Absorbed Pulse Energy
585 J
Efficiency
95 %
Safety Features
noise immunity, short-circuit protection, high-voltage surge protection, protection against major power outage, overload protection

Connectors

Number and Type of Power Output Connectors
terminal block
Number of Power Output Connectors (UPS)
0
Connectors/Ports
USB Type B, RS-232, EPO, SNMP slot
Port Layout
vertical

Battery

Battery Type
sodium-ion
Charging Time
1 h
Battery Voltage and Capacity
48V/4.8Ah
Replaceable Batteries
yes
Number of Batteries
5 pcs
External Battery Connection
yes

Additional Information

Housing Protection Class
IP20
Functions and Modes
ECO mode, bypass
Cold Start
yes
Display
LCD display
LED Indicators
inverter operation, UPS error, bypass mode, battery-powered
Noise Level
55 dB
Operating Temperature
from -20 to +40 °C
Package Contents
documentation, USB cable

Dimensions and Weight

Depth
450 mm
Width
190 mm
Height
700 mm
Weight
33.9 kg

Description

The Ippon Na+ TA 10K online double-conversion UPS is designed for servicing sensitive electrical equipment. The model with an apparent output power of 10000 VA is suitable for use with gas boilers, server stations, medical equipment, and computers. The UPS protects equipment from voltage fluctuations in the range of 110-300 V, high-voltage surges, short circuits, overloads, and complete power outages.
A terminal block is provided for connecting equipment. A slot for an SNMP expansion card enables remote monitoring. The LCD display shows the main operating parameters. The Bypass mode automatically switches device power to the mains, bypassing the power circuit in case of overheating or other emergency situations. The Ippon Na+ TA 10K UPS is equipped with a battery module featuring five sodium-ion backup power sources. Under full load, the battery runtime is 3.5 minutes.