UPS HIDEN EXPERT UDC9202H-48

#9119631

UPS HIDEN EXPERT UDC9202H-48

[double conversion, 2000 VA, 1600 W, 4 × CEE 7 (Type F outlet), RS-232, SNMP slot, USB] details

Not on sale

  • Characteristics
  • Feedback 0
  • Instructions and files

Characteristics UPS HIDEN EXPERT UDC9202H-48

General parameters

Type
UPS
Model
HIDEN EXPERT UDC9202H-48
Main Color
black
Type
double conversion
Form Factor
Tower
Power Cable Length
0 m

Technical parameters

Maximum Output Power
2000 VA
Effective Power Output
1600 W
Minimum Input Voltage
110 V
Max Input Voltage
288 V
Min Input Frequency
40 Hz
Max Input Frequency
70 Hz
Output Voltage Stability
± 1 %
Minimum Output Frequency
49.75 Hz
Max Output Frequency
60.3 Hz
Wave Form
pure sine wave
Delay When Switching to Battery
0 ms
Efficiency
91 %

Connectors

Number and Type of Power Output Connectors
4 × CEE 7 (Type F outlet)
Number of Power Output Connectors (UPS)
4
Connectors/Ports
USB, RS-232, SNMP slot
Extra Ports
RJ-11, RJ-45
Port Layout
vertical

Battery

Charging Time
8 h
Replaceable Batteries
yes
Number of Batteries
4 pcs
External Battery Connection
yes
Battery Included
none

Additional Information

Housing Protection Class
IP20
Functions and Modes
emergency power-off (EPO), ECO mode, bypass
Cold Start
yes
Display
LCD display
LED Indicators
UPS error, AC power input, bypass mode, AC power output, load level
Noise Level
50 dB
Operating Temperature
from 0 to +40°C
Package Contents
power cable, RS-232 cable, documentation, USB cable
Features
connects to external battery packs (not included)

Dimensions and Weight

Depth
427 mm
Width
190 mm
Height
336 mm
Weight
8.5 kg

Description

The HIDEN EXPERT UDC9202H-48 double-conversion UPS with a power rating of 2000 VA is suitable for powering sensitive equipment that requires a pure sine wave. The model is designed for the safe operation of PCs, servers, workstations, Smart Home systems, gas boilers, pumps, and medical equipment. The unit supports 3 modes: EPO for emergency power off, bypass for continuous equipment power in case of UPS failure, and ECO for energy saving. Cold start allows starting connected equipment for several minutes to properly shut down systems or save important data.
The HIDEN EXPERT UDC9202H-48 UPS features 4 built-in batteries. If needed, external battery packs can be added to extend runtime. Four CEE 7 Euro sockets are provided for connecting equipment. RS-232 and USB interfaces alongside an SNMP slot allow managing the UPS via computer and configuring settings remotely. RJ-11 and RJ-45 ports provide surge protection for telephone lines and wired Ethernet networks. Thanks to its tower form factor, the unit can be placed directly on a desk or floor without requiring server racks.