Gas boiler Baxi ECO Life 1.31F wall-mounted

#9966067

Gas boiler Baxi ECO Life 1.31F wall-mounted

[single-circuit, 31 kW, 230 V/50 Hz, power consumption - 110 W, 450 mm x 766 mm x 340 mm] details

Not on sale

  • Characteristics
  • Feedback 0
  • Instructions and files

Characteristics Gas boiler Baxi ECO Life 1.31F wall-mounted

General information

Type
gas boiler
Model
Baxi ECO Life 1.31F
Manufacturer Code
[НС-1484405]
Boiler Type
traditional

Basic characteristics

Fuel Type
liquefied gas, natural gas
Installation/Assembly
wall-mounted
Combustion Chamber Type
closed
Max Performance (Efficiency)
92.3 %
Power
31 kW
Number of Circuits
single-circuit
Boiler Intended Use
heating
Voltage
230 V/50 Hz
Power Consumption
110 W
Heating Connection Diameter
3/4"
Gas Connection Diameter
3/4"
Natural Gas Consumption (min / max)
3.52 m³/h
Liquefied Gas Consumption (min / max)
2.63 kg/h
Chimney Diameter
60/100 (80/80) mm
Expansion Tank Volume
10 L
Built-In Circulation Pump
yes
Overheating Protection
yes
Self-Diagnostics
yes
Anti-Freeze
yes
Package Contents
wall plugs, metal washer, mounting jig, temperature sensor, hydraulic seal kit, flow restrictor with filter, documentation, mounting rail
Extra
flame ionization control

Dimensions and Weight

Width
450 mm
Height
766 mm
Depth
340 mm
Weight
36 kg

Description

The Baxi ECO Life 1.31F gas boiler features flexible configuration of its operating parameters, allowing you to set the optimal temperature mode in the heating system. The model is equipped with weather-compensated automation, making it possible to connect an outdoor temperature sensor. Additional functionality is provided by full compatibility with the BAXI Connect+ remote control system. The boiler's LCD display shows information about the current temperature mode. A programmable timer and room thermostat can be connected to the device.
The operation of the Baxi ECO Life 1.31F gas boiler is continuously monitored by an electronic self-diagnostic system, which immediately notifies the user of malfunctions via symbol indicators. The pump and three-way valve are protected against jamming due to automatic activation every 24 hours. The heating system includes a pressure switch that triggers in case of insufficient water pressure.