UPS Ippon Back Verso 600

#0114408

UPS Ippon Back Verso 600

[spare, 600 VA, 300 W, 6 × CEE 7 (Type F outlet)] details

Not on sale

  • Characteristics
  • Feedback 149
  • Instructions and files

Characteristics UPS Ippon Back Verso 600

General parameters

Type
UPS
Model
Ippon Back Verso 600
Manufacturer Code
[751617]
Main Color
black
Type
spare
Form Factor
Brick

Technical parameters

Maximum Output Power
600 VA
Effective Power Output
300 W
Minimum Input Voltage
170 V
Max Input Voltage
270 V
Min Input Frequency
45 Hz
Max Input Frequency
65 Hz
Output Voltage Stability
± 10 %
Minimum Output Frequency
49 Hz
Max Output Frequency
61 Hz
Wave Form
modified sine wave
Runtime
1 min (300W)
Delay When Switching to Battery
12 ms
Max Absorbed Pulse Energy
125 J
Efficiency
95 %
Safety Features
data transmission line protection, short-circuit protection, surge protection, overload protection

Connectors

Number and Type of Power Output Connectors
6 × CEE 7 (Type F outlet)
Number of Power Output Connectors (UPS)
4
Extra Ports
RJ-11, RJ-45
Port Layout
horizontal

Battery

Battery Type
lead-acid
Charging Time
10 h
Battery Voltage and Capacity
12V/5Ah
Replaceable Batteries
none
Battery Hot Swap
none
Number of Batteries
1 pcs
External Battery Connection
none
Battery Included
yes

Additional Information

Housing Protection Class
IP20
Cold Start
none
Display
none
LED Indicators
mains power, UPS error, overload, low battery level
Sound Signals
UPS fault (error), overload, low battery level, battery-powered
Noise Level
45 dB
Operating Temperature
from 0 to +40°C
Package Contents
documentation

Dimensions and Weight

Depth
320 mm
Width
125 mm
Height
86 mm
Weight
2.82 kg

Description

The IPPON Back Verso 600 UPS is a device equipped with six Euro-style sockets that protect user equipment from power surges. Four of these sockets provide uninterruptible power supply to devices. The model operates stably within an input voltage range of 170 to 260 V. A full charge takes 16 hours. LED indicators display the UPS status.
The IPPON Back Verso 600 belongs to the standby (off-line) type of uninterruptible power supplies. This device automatically adjusts voltage and also protects user equipment from overload, high-voltage spikes, and short circuits. Within 6 ms of detecting a mains failure, the UPS switches connected equipment to battery power. When powering four devices simultaneously, the model runs for 5 minutes, and for 11 minutes under half load. If the UPS battery fails, it can be replaced with a new one.