UPS HIDEN EXPERT ULS2000E

#9119615

UPS HIDEN EXPERT ULS2000E

[linear-interactive, 2000 VA, 1200 W, 2 × IEC 320 C13 (computer), 4 × CEE 7 (Type F outlet), USB] details

Not on sale

Total Output Power (VA)
  • Characteristics
  • Feedback 0
  • Instructions and files

Characteristics UPS HIDEN EXPERT ULS2000E

General parameters

Type
UPS
Model
HIDEN EXPERT ULS2000E
Main Color
black
Type
linear-interactive
Form Factor
Tower

Technical parameters

Maximum Output Power
2000 VA
Effective Power Output
1200 W
Minimum Input Voltage
220 V
Max Input Voltage
230 V
Min Input Frequency
50 Hz
Max Input Frequency
60 Hz
Output Voltage Stability
± 10 %
Minimum Output Frequency
49 Hz
Max Output Frequency
61 Hz
Wave Form
modified sine wave
Delay When Switching to Battery
6 ms
Safety Features
short-circuit protection, overcharge protection, deep discharge protection

Connectors

Number and Type of Power Output Connectors
2 × IEC 320 C13 (computer), 4 × CEE 7 (Type F outlet)
Number of Power Output Connectors (UPS)
6
Connectors/Ports
USB
Extra Ports
RJ-11, RJ-45
Port Layout
vertical

Battery

Battery Type
lead-acid
Charging Time
5 h
Battery Voltage and Capacity
24V/7Ah
Replaceable Batteries
yes
Number of Batteries
2 pcs
External Battery Connection
none
Battery Included
yes

Additional Information

Cold Start
yes
Display
none
LED Indicators
mains power, UPS error, overload, battery-powered, battery charging, low battery level
Noise Level
40 dB
Operating Temperature
from 0 to +40°C
Package Contents
documentation, USB cable

Dimensions and Weight

Depth
343 mm
Width
135 mm
Height
208 mm

Description

The HIDEN EXPERT ULS2000E line-interactive UPS generates a simulated sine wave. With a power of 2000 W, it can power and ensure the safe operation of PCs, office equipment, and network devices in unstable power grids. Switching to the battery takes 6 ms. The package includes 6 lead-acid batteries. They can be replaced with more powerful ones, thereby increasing the autonomous operation time.
The HIDEN EXPERT ULS2000E UPS is equipped with IEC 320 C13 interfaces, CEE 7 Euro sockets, and USB for connecting various equipment. Through RJ-11 and RJ-45 connectors, you can set up protection for modems, routers, telephone lines, and Ethernet cables. Cold start allows powering equipment from the unit in the absence of voltage in the main power grid. Thanks to the Tower form factor, the model can be placed on the floor, desk, or other horizontal surfaces. The operating noise of the UPS does not exceed 40 dB. This is comparable to a whisper and does not disturb people in the room.