UPS Powercom SNT-2000

#9111565

UPS Powercom SNT-2000

[double conversion, 2000 VA, 2000 W, 1 x IEC 320 C19 (computer), 8 × IEC 320 C13 (computer), RS-232, SNMP slot, USB] details

Not on sale

  • Characteristics
  • Feedback 0
  • Instructions and files

Characteristics UPS Powercom SNT-2000

General parameters

Type
UPS
Model
Powercom SNT-2000
Main Color
black
Type
double conversion
Form Factor
Rack/Tower
Power Cable Length
0 m

Technical parameters

Maximum Output Power
2000 VA
Effective Power Output
2000 W
Minimum Input Voltage
120 V
Max Input Voltage
300 V
Min Input Frequency
50 Hz
Max Input Frequency
60 Hz
Output Voltage Stability
± 2 %
Minimum Output Frequency
50 Hz
Max Output Frequency
60 Hz
Wave Form
pure sine wave
Delay When Switching to Battery
0 ms
Max Absorbed Pulse Energy
1620 J
Safety Features
short-circuit protection, overcharge protection, overload protection

Connectors

Number and Type of Power Output Connectors
1 x IEC 320 C19 (computer), 8 × IEC 320 C13 (computer)
Number of Power Output Connectors (UPS)
8
Connectors/Ports
USB, RS-232, SNMP slot
Port Layout
rack-mounted

Battery

Battery Type
lead-acid
Charging Time
3 h
Battery Voltage and Capacity
12V/7Ah
Replaceable Batteries
yes
Battery Hot Swap
yes
Number of Batteries
3 pcs
External Battery Connection
yes
Battery Included
yes

Additional Information

Functions and Modes
emergency power-off (EPO), bypass
Cold Start
yes
Display
LCD display
LED Indicators
battery level, battery-powered
Sound Signals
UPS fault (error), overload, low battery level, battery-powered
Noise Level
50 dB
Operating Temperature
from 0 to +40°C
Package Contents
fastening kit, power cable, RS-232 cable, documentation, rack-mounting kit, USB cable

Dimensions and Weight

Depth
635 mm
Width
428 mm
Height
84 mm
Weight
28.5 kg

Description

The 2000 VA double-conversion Powercom SNT-2000 UPS is suitable for powering sensitive equipment: gas boilers, medical devices, and pumps. The model is equipped with three 12V/7Ah lead-acid batteries. If needed, external battery packs can be connected to extend runtime. The model supports hot-swappable batteries, allowing uninterrupted operation of the UPS and connected equipment. IEC 320 C19 and IEC 320 C13 outlets are used for connecting devices. RS-232, USB interfaces, and an SNMP slot are provided for remote monitoring and configuration management.
The Powercom SNT-2000 UPS is protected against short circuits, overloads, and overcharging. The EPO port allows for emergency power off during critical situations. The bypass automatically switches power to the main grid in the event of a UPS fault. The Rack/Tower form factor allows installation on the floor, on a desk, or in a rack. Operating status can be monitored on the LCD display as well as via LED indicators and audible alarms.