UPS IPPON Innova RT II 1000

#9105026

UPS IPPON Innova RT II 1000

[double conversion, 1000 VA, 1000 W, 8 × IEC 320 C13 (computer), dry contacts, RS-232, SNMP slot, USB] details

Not on sale

  • Characteristics
  • Feedback 0
  • Instructions and files

Characteristics UPS IPPON Innova RT II 1000

General parameters

Type
UPS
Model
IPPON Innova RT II 1000
Manufacturer Code
[1398359]
Main Color
black
Type
double conversion
Form Factor
Rack/Tower
Power Cable Length
0 m

Technical parameters

Maximum Output Power
1000 VA
Effective Power Output
1000 W
Minimum Input Voltage
160 V
Max Input Voltage
300 V
Min Input Frequency
40 Hz
Max Input Frequency
70 Hz
Output Voltage Stability
± 1 %
Minimum Output Frequency
49.9 Hz
Max Output Frequency
60.1 Hz
Wave Form
pure sine wave
Runtime
4 min (1000W)
Max Absorbed Pulse Energy
296 J
Efficiency
89 %
Safety Features
short-circuit protection, surge protection, overload protection

Connectors

Number and Type of Power Output Connectors
8 × IEC 320 C13 (computer)
Number of Power Output Connectors (UPS)
8
Connectors/Ports
USB, dry contacts, RS-232, SNMP slot
Port Layout
rack-mounted

Battery

Battery Type
lead-acid
Charging Time
3 h
Battery Voltage and Capacity
12V/7Ah
Replaceable Batteries
yes
Battery Hot Swap
none
Number of Batteries
3 pcs
External Battery Connection
yes
Battery Included
yes

Additional Information

Functions and Modes
ECO mode
Cold Start
none
Display
LCD display
LED Indicators
load, events, work mode
Noise Level
45 dB
Operating Temperature
from 0 to +40°C
Package Contents
fastening kit, removable support feet, documentation, power cable x3, USB cable
Features
height 2U

Dimensions and Weight

Depth
438 mm
Width
445 mm
Height
85.5 mm
Weight
14.3 kg

Description

UPS IPPON Innova RT II 1000 with a power rating of 1000 VA with double conversion forms a clean sine wave and can power sensitive equipment. The unit can be connected to a gas boiler, pump, servers. In case of a power outage the UPS will provide up to 4 minutes of autonomous operation. This is enough to properly finish the operation of the equipment, preserve important data. Through the RS-232 and USB ports the UPS is connected to a PC for remote monitoring and configuring settings. A card is installed in the SNMP slot, which helps monitor input/output voltage, load and battery charge in real time via a web interface or software. Dry contacts are used to transmit alarm signals to external controllers.
The UPS IPPON Innova RT II 1000 supports ECO mode, when the unit increases efficiency to its limit values and at the same time consumes minimum electricity. The kit includes 3 lead-acid batteries 12V/7Ah. They can be replaced with more powerful ones or connect external batteries to increase autonomous operating time. The UPS is implemented in Rack/Tower form factor. It can be installed vertically on the floor/desk or horizontally in a 19-inch server rack.